Failure Analysis of a Fuel Cell Terminal Lug due to Hard Coating
Two crimping dies (T & B Nos. 45 and 42), were reported to be used sequentially to secure an electrical cable to the lug. Visual examination, chemical, mechanical and metallographic analyses was performed on the submitted strap sections to look for…